               Clinical Pharmacy-Pharm D        Level Three        2  Semester       2024/2025      Pharmaceutical Technology (PT 607)


               Lab (5): (Weight Uniformity Test)


               Weight Variation:


               In manufacturing tablets our aim is to produce tablet that can be validated as to its safety,
               efficacy, and reliability; so, each tablet is designed to have certain weight and to check the

               uniformity of weight.


              1-   20 tablets previously selected at random were weighed. Then the average weight was

                   determined.
              2-   Tablets were weighed individually and the percentage deviation of its weight from the

                   average weight was determined for each tablet.

              3-  The  deviation  of  individual  weight  from  the  average  weight  should  not  exceed  the
                   pharmacopeial limits.


               The tablets meet the pharmacopeial limits weight variation test if:


               No more than two tablets of 20 tablets are outside the percentage


               limit and no tablet differs by more than twice the percentage limit.


               According to USP (most commonly used):
















               According to BP: