Step 2:                               5    The locaƟ on is not prone to    2     Locate the water heater’s

        Verify that the locaƟ on                    physical damage by vehicles,          circuit breaker and turn it OFF
                                                                                          (or remove the circuit’s
                                                    Ň ooding, or other risks.

        is appropriate                                                                    fuses).
                                                                                          On the old water heater,
        Before installing your water heater,                                        3     remove the electrical
        ensure that:
                                                                                          junction box access panel.
                                                  Vehicle
                                                  Stop                             Using a non-contact circuit tester,
               The water heater will be:
          1    • Installed indoors close to                                        check the wiring to make certain the
               the center of the plumbing                  Drain        Drain      power is OFF.
                                                           Pan
               system.
                                                                                     WARNING! Working on an energized
                                             Figure 8 -ര In a garage, install a vehicle stop
        •  In a suitable drain pan piped to an  to avoid water heater damage.      circuit can result in severe injury or
          adequate floor drain or external                                         death from electrical shock.
                                                    Avoid locaƟ ons such as aƫ  cs,
          to the building (Figure 6 on page    6                                          Disconnect the electrical
          8).                                       upper Ň oors, or where a leak   4     wires.
                                                    might damage the structure
        • In an area that will not freeze    or furnishings. Due to the normal            Open a hot water faucet and
                                             corrosive acƟ on of water, the tank will   5
        •  In an area that is suitable for install-                                       let the hot water run unƟ l it is
          ing the water heater vertically    eventually leak. To minimize property        cool (This may take 10
                                             damage from leaks, inspect and
                                                                                   minutes or longer).
               The locaƟ on has adequate     maintain your water heater in accor-
          2    space (clearances) for periodic   dance with this manual’s instrucƟ ons.
               servicing.                    Install a suitable drain pan under the                                    INSTALLATION
                                             water heater piped to an adequate
               The Ň oor can support the     drain. Inspect the drain pan, pipes, and
          3    weight of a full water heater.  surrounding area regularly and Į x any

                                             leaks found. Drain pans are available at
               Your area is not prone to         your local plumbing supplier. Leaks are
          4    earthquakes. If it is, use    frequently in the plumbing system

               special straps as required by   itself and not the water heater.
                                                                                   Figure 9 -രLet the hot water run until it is cool.
        local building codes.
        NOTICE: The state of California re-    Step 3:                               WARNING! Be sure the water runs
                                                                                   cool before draining the tank to reduce
        quires bracing, anchoring, or strapping   Removing the old water
        the water heater to avoid its moving                                       the risk of scalding.
        during an earthquake. Contact local   heater                                6     Connect a garden hose to the
        uƟ liƟ es for code requirements in your     Read each installaƟ on step           drain valve and place the
        area, visit hƩ p://www.dsa.dgs.ca.gov,  1   and decide if you have the            other end of the hose in a
        or call 1-916-445-8100 and request          necessary skills to install the   drain, outside, or a bucket. (Note that
        instrucƟ ons. Other locaƟ ons may have  water heater. Only proceed if you can   sediment in the boƩ om of the tank
        similar requirements. Check with your  safely perform the work. If you are not   may clog the valve and prevent it
        local and state authoriƟ es.         comfortable, have a qualiĮ ed person   from draining. If you can’t get the
                                                                                   tank to drain, contact a qualiĮ ed
                                             perform the installaƟ on.
                                                                                   person.)