4.1.2 Back of House Lighting                            •	 Occupancy detectors must be positioned
                                                            so that they are not triggered by traffic in the
Supply and install all light fittings (internal and         corridor outside the door. In general terms
external) in accordance with the light fittings             this means fairly close to the wall and offset
schedule and requirements of the project.                   to the side from the leading edge of the
                                                            door, so that it cannot “see” passers-by.
•	 Light fittings must be adequately supported
    within the suspended ceiling or by suitable         •	 Lighting in the customer area shall be
    solid fixings.                                          independently switched, with the switches
                                                            located on the staff side of the door/counter.
•	 Additional hangers may be required for
    suspended ceilings if no independent                •	 No light switches may be located in
    support is provided.                                    cupboards of any kind, including electrical
                                                            cupboards.
•	 Terminate all suspended ceiling light fittings
    at a suitable ( Clix or similar) plug and socket    •	 A light switch should be located at the final
    located within the accessible ceiling space             entry/exit door, controlling sufficient lighting
    via flexible cord from the plug to the supply           to enable the staff to see their way to the
    terminals of the light fittings, ensuring that the      main switch bank.
    sockets are properly seated and not liable
    to accidentally part.                               •	 A separately switched lighting circuit shall
                                                            be provided to serve 1No. light fitting as
•	 Alternatively: note that the fittings supplied           a night security light in the vicinity of the
    by Microlights Ltd may be installed using               extract canopy or as otherwise agreed with
    the special connectors available from                   the DPG Project Manager.
    Microlights to suit, rather than Clix. However
    the quoted price of the fitting does not            •	 Ensure that all lamps/tubes used are of the
    include the connectors, these must be                   same colour temperature appearance,
    ordered separately.                                     (“White”) and that fittings are positioned
                                                            such that all lamps run in the same direction.
•	 Surface fixed light fittings are only to be used
    where absolutely necessary and are to be            •	 “White” colour tubes MUST be used to
    directly wired with concealed cabling.                  reduce the energy consumption to within
                                                            the Building Regulations energy saving
•	 All light fittings in the main working area shall        regulations.
    be controlled by a wall mounted switch bank
    positioned in a suitable location, having           •	 A protected fluorescent light fitting, to IP 65,
    regard to any freestanding equipment                    will be required inside the extract canopy.
    which might obscure it.                                 This MUST be supplied with S/S clips (not
                                                            plastic) to hold the cover and should be
•	 Light fittings in the office, store rooms,               positioned so that it is not directly above the
    toilets, staffrooms and any other occasional            ends of the oven cooking chamber.
    use areas shall be controlled by suitable
    ‘occupancy detectors’, to ensure that lights        •	 ALL light fittings must incorporate diffusers,
    are not left switched on in unoccupied                  or similar protection, to contain the debris if
    areas.                                                  tubes or bulbs shatter for whatever reason.