Page 67 - B8773-AEW-XX-XX-PP-A-0001_[P1]_Contractors Manual
P. 67
4.2.7 Oven and Fan Wiring 4.2.8 Testing and Completion
The main site electrician will be required to Upon completion the electrical installation shall
supply simple on/off switches and wire to be fully tested, proved and working.
isolator adjacent to each fan.
• Full test results and the appropriate
The electrical supply to each oven socket must certification shall be provided for all electrical
be independent, so that in the event that one systems including emergency lights and fire
circuit breaker trips, power is not lost to both alarms.
ovens at the same time. Note also that although
the PS 200/540 and XLT3255 ovens will run from a • An emergency telephone number for the
standard twin 13a S/S/O, the PS360EWB and PS electrician, MUST be written on the fire alarm
555 will require 2No. 20A rated sockets & plugs panel for use in the event of electrical/
(Reyrolle type) operating faults.
• The reset code MUST be written on the fire
alarm panel.
• Provide a comprehensive operation and
maintenance manual including details of
the systems installed and record drawings
indicating the layout and interconnections
of all items.
• Allow to demonstrate the operation of all
electrical systems to the end user at hand
over.
• Final invoices will not be paid until test
certificates are received.
4.2.7 - 4.2.8 Oven and Fan Wiring and Testing and Completion 3 February 2016