4.6 Ventilation and Air Conditioning

From the beginning of 2013, the standard                   •	 HVCA - DW144 Specification for Sheet Metal
ceiling colour in Customer area and Bake and                   Ductwork
Serve has changed from standard white to RAL
7037 ( grey) for both new stores and re-fits. All          •	 HVCA - DW172 Guide to Good Practice for
ceilin grilles and air con ceiling face plates will            Kitchen Ventilation Systems
therefore need spraying to match – White or
other colours will not be acceptable in these              •	 HVCA – RUAG70 Guide to Good Practice for
area’s (BOH is not affected and will remain in                 Refrigeration
white.)
                                                           •	 The Building Regulations
                                                           •	 Gas Safety (Installation and Use) Regulations

                                                               1998

Please note also that a series of decorative fins will be  All plant, ducts, pipes cables etc. shall be
suspended from the grey ceilings at 1200mm centres.        adequately protected against accidental
The support frames for these may in some instances have    damage, corrosion and external environment
an effect on duct runs and should be discussed with the    and shall be capable of safe decontamination
shopfitter on site to minimize any conflicts.              and removal in the future without disturbing
                                                           other services. Pipes and ducts shall be
                                                           adequately sized, kept as short as practicable,
                                                           leak-proof with a minimum number of joints and
                                                           have provision for routine maintenance.

4.6.1 Overview                                             All facilities shall be designed to prevent the
                                                           ingress or egress of rodents, vermin and insects.
The project includes all of the mechanical
services works associated with the fitting out of          The HVAC contractor shall supply the client with
an existing shell unit to create a fully operational       system design drawings, prior to manufacture
pizza delivery operation. Domino’s operation               and installation. The HVAC contractor will
produces very little grease and the extract                also supply a comprehensive operation and
system is predominantly removing heat and gas              maintenance manual on completion of the
combustion fumes.                                          works.

All work shall be carried out in accordance                For projects in England and Wales, the HVAC
with the latest relevant British ( or Irish where          contractor shall also demonstrate compliance
appropriate)                                               with Building Regulations Approved Documents
and European Standards, Statutory Regulation               L2A & L2B. This will include:
and Byelaws together with the following                    •	 Provision of details of the efficiency and
publications
•	 CIBSE Codes and Guides to Current Practice                  controls of heating, cooling and ventilation
•	 Water Authority By Laws                                     systems in accordance with the Non-
•	 HVCA – DW143 Practical Guide to Ductwork                    Domestic Heating, Cooling and Ventilation
                                                               Compliance Guide (2006).
    Leakage Testing

4.6.1  Ventilation and Air Conditioning - Overview         3 February 2016