Health and Safety      Workplace health, safety and welfare
 Executive  3.3 Staff WC Provision





 ACOP   21    ■  the facilities should be fitted with doors at entrances and exits unless
       The  provisions  for  a  staff  WC  should  be  in
           other measures are taken to ensure an equivalent degree of privacy.
       accordance  with  Table  1,  Regulation  21  of
        Minimum numbers of facilities
       the  Workplace  (Health,  Safety  and  Welfare)
        197  Table 1 shows the minimum number of toilets and washbasins that
       Regulations  1992.  There  should  be  1No.  toilet
        should be provided where both men and women are working. Column 1 refers
        to the maximum number of workers likely to be in the workplace at any one
       provided as a minimum where there are up to
        time. If separate toilets are provided for a group of workers (eg men, women,
        office workers or manual workers), a separate calculation should be made for
       5No. members of staff on the premises at any
        each group. More facilities may be necessary if, for example, breaks are
        taken at set times or workers finish work together and need to wash before
       one time.
        leaving.
        Table 1 Number of facilities needed per number of people at work
        1               2                3
        Number of people    Number of cubicles  Number of washbasins
        at work
        1 to 5          1                1
        6 to 25         2                2
        26 to 50        3                3
        51 to 75        4                4
        76 to 100       5                5

 Guidance    21  198  Table 1 provides advice on provision for mixed workplaces. However, where it
        may be necessary to provide urinals for use by men, then the advice in Table 2 may
        be followed.
 ACOP   21  199  Table 2 may be followed as an alternative to column 2 of Table 1 if toilets
       Standard staff toilet pack to consist of:
        are only used by men. A urinal may either be an individual urinal or a section
        of urinal space which is at least 600 mm long.
        Table 2 Number of facilities needed per number of men at work
       •  WC
       •  Wash hand basin with mixer tap
        1
                                         3
                        2
                        Number of cubicles
                                         Number of urinals
        Number of men
       •  Toilet roll holder
        at work
       •  Soap dispenser                 1
        1 to 15
                        1
       •  Hand dryer / paper towel dispenser
                                         1
                        2
        16 to 30
       •  Mirror        2                2
        31 to 45
       •  Sanitary bin   3               2
        46 to 60
       •  Litter / paper towel bin       3
                        3
        61 to 75
       •  New store signage pack         3
                        4
        76 to 90
       •  Shelves for storage (to be confirmed between
                                         4
                        4
        91 to 100
          Franchisee and Principal Contractor)
                             Page 39 of 60