4.1.3 Water Supply - Best Practice Guidance
          The water supply is to be 25mm usually MDPE,
          unless the site is contaminated and then barrier
          pipe would be required

          Best Practice
          •  Lay  25mm  blue  MDPE  water  supply  pipe
             from the store to the boundary at a minimum
             depth of 750mm and a maximum depth of
             1300mm
          •  (If there is no private land then this must be
             laid minimum 750mm below finished ground
             level abutting the wall, coiled and capped)
          •  Sufficient pipe must be available to enable
             this to reach the water main.  The highway
             end must be coiled and capped
          •  To  duct  and insulated the  supply where  it
             enters the building
          •  To fit a British Standard internal stop tap