Page 60 - B8773-AEW-XX-XX-PP-A-0001_[P4]_Contractors Manual
P. 60

4.1 Lighting
                            D R A F T


       4.1.1 Front of House Lighting
       Customer areas  and kitchen lighting is usually
       a mix of spotlights, wall wash, ambient lighting
       and feature pendants. General light fittings will
       be  supplied  sprayed  to  RAL  7039  –  NOTE:  This
       NOT the same colour as the ceiling (RAL 7037).


       General  principles  for  positioning  each  fitting
       are as follows:


       •  Wall  wash  lights  to  be  fitted  at  1200mm
          centres (alternate tiles) for the full extent of
          all graphic / feature walls (except the timber
          wall  which  will  have  down  lights  angled
          towards the wall) and white tiled walls. Each
          light to be installed between 450-600mm off
          the wall face.
       •  Spot lights to be installed in specific locations
          only,  as  accent  lights:  Typically  customer
          facing, the length of slap table (in line with
          the counter), 2No over cut table.
       •  Downlights  are  to  be  used  throughout  the
          rest of the Bake & Serve and Customer Area
          ceiling  to  provide  adequate  task  lighting,
          generally one fitting per 6 ceiling tiles.
       •  Feature  pendant  lights  are  to  be  located
          over communal tables in the customer area,
          in accordance with the project drawings.
       •  All  pendants  to  be  to  be  hung  1950mm
          AFFL to underside and centred to the sit up
          bar / table. The pendants have a standard
          cable length  - between 600-850mm. If the
          customer area ceiling is higher than 2500mm
          AFFL longer cables need to be fitted.