4.1.2 Back of House Lighting
Supply and install all light fittings (internal and • Lighting in the customer area shall be
external) in accordance with the light fittings independently switched, with the switches
schedule and requirements of the project. located on the staff side of the door/counter.
• No light switches may be located in
• Light fittings must be adequately supported cupboards of any kind, including electrical
within the suspended ceiling or by suitable cupboards.
solid fixings. • A light switch should be located at the final
• Additional hangers may be required for entry/exit door, controlling sufficient lighting
suspended ceilings if no independent to enable the staff to see their way to the
support is provided. main switch bank.
• Terminate all suspended ceiling light fittings • A separately switched lighting circuit shall
at a suitable ( Clix or similar) plug and socket be provided to serve 1No. light fitting as
located within the accessible ceiling space a night security light in the vicinity of the
via flexible cord from the plug to the supply extract canopy or as otherwise agreed with
terminals of the light fittings, ensuring that the the DPG Project Manager.
sockets are properly seated and not liable • Ensure that all lamps/tubes used are of the
to accidentally part. same colour temperature appearance,
• Surface fixed light fittings are only to be used (“White”) and that fittings are positioned
where absolutely necessary and are to be such that all lamps run in the same direction.
directly wired with concealed cabling. • “White” colour tubes MUST be used to
• All light fittings in the main working area shall reduce the energy consumption to within
be controlled by a wall mounted switch bank the Building Regulations energy saving
positioned in a suitable location, having regulations.
regard to any freestanding equipment • A protected fluorescent light fitting, to IP 65,
which might obscure it. will be required inside the extract canopy.
• Light fittings in the office, store rooms, This MUST be supplied with S/S clips (not
toilets, staffrooms and any other occasional plastic) to hold the cover and should be
use areas shall be controlled by suitable positioned so that it is not directly above the
‘occupancy detectors’, to ensure that lights ends of the oven cooking chamber.
are not left switched on in unoccupied • ALL light fittings must incorporate diffusers,
areas. or similar protection, to contain the debris if
• Occupancy detectors must be positioned tubes or bulbs shatter for whatever reason.
so that they are not triggered by traffic in the • Lighting in ancilliary areas i.e other than
corridor outside the door. In general terms Bake & Serve and Customer areas should
this means fairly close to the wall and offset normally be modular lay-in fittings and
to the side from the leading edge of the should normally be LED luminaires rather
door, so that it cannot “see” passers-by. than fluorescents.