       •  Terminate  telephone extension lines. The          UK “Self-build” franchisees will need to speak to
          standard  is:  4No.  on  the  counter,  1No.       their alarm and phone system companies and
          at  drivers  table  (If  the  shop  is  ready,  fix   make them aware of this. This does not affect
          handset(s)  on  the  wall  as  required.  If  the   ROI stores
          shop is not ready, then turn the back plate               A Toshiba system should be programmed
          round on the phone ready for the shopfitters       as standard to operate as follows:
          to fix on the wall), 1No. in office, 2No. “wiring   Pick Handset UP
          only”  positions,  wall  mounted  (location  will   Dial 9 for a line, then dial the required number
          vary).                                             Wait for a few seconds,
                                                             –  Phone  display  will  then  say,  “Enter  Account
       If the counter is small, the number of extensions     Code now” Dial the A/C code, which is:  1 9  7 1
       on the counter will reduce from 4 to 3No. or in       Phone will then automatically continue to dial
       very  exceptional  circumstances,  2No.  If  there    the number which was previously entered.
       are less than 4 handsets on the counter, there
       will be additional wall mounted  handsets to          Other system manufacturers may be different
       compensate.                                           but should be programmed to achieve a similar
                                                             result.
       There may be additional lines to terminate if a
       larger system is installed.                           Domino’s Pizza Caller ID Cable Installation Guide
       The number of phones on the counter is normally       For a standard system, the site electricians will
       governed  by  the  number  of  bays  within  the      run two CAT5 data cables for Caller ID. These
       counter,  and there  is always one  handset in        cables are to be left coiled in the ceiling near to
       each  counter  bay  (  excluding  the  “disabled/     the BT DP box, at one end, and then run to the
       COLLECT” bay).                                        office  computer  cabinet  and  terminated  with
                                                             RJ45 sockets by the site electrician, at the other
       •  Connect  the  previously  laid  in  cables  for    end.
          the Caller ID, to the telephone system – see       These two cables need punching down into the
          below for ‘punch-down’ details.                    NTTP box by the telephone engineer, as follows:
       •  Leave telephone system programmed and              First cable:
          tested - if the site is not ready for the phones   •  Line 1, orange and white  &  orange.
          to go out, they should be left in a box in the     •  Line 2, green and white & green.
          office or other secure location.                   •  Line 3, blue and white &  blue.
       •  Most UK stores are now automatically part of       •  Line 4, brown and white &  brown
          a “BT Featureline” package. As a result, an
          additional “9” needs to be programmed into         Second cable:
          phone systems and alarm systems to enable          •  Line 5, orange and white  &  orange.
          connection to the BT Featureline network.          •  Line 6, green and white & green.
                                                             •  Line 7, blue and white &  blue.
                                                             •  Line 8, brown and white &  brown



       4.4.4                       Telephone System                                      3 February 2016