Page 82 - B8773-AEW-XX-XX-PP-A-0001_[P4]_Contractors Manual
P. 82

both ends and labeled “ Screens”R A F T




       The  Digital  Video  Recorder  is  to  be  housed  in
       a  metal  lockable  enclosure  .  A  19”  flatscreen
       CCTV monitor to be installed into the manager’s
       office.

       A Netgear (or similar) router is to be installed in
       the counter  computer  cupboards to connect
       to the digital recorder in the manager’s office.


       The following items will be required to be installed
       by the site electrician for the Menu Screen and
       CCTV  installations  (all  CLEAN  sockets,  red
       coloured):
       •  Double  13A  UNSWITCHED  spur  under  the
          office worktop at the Comms Tower end
       •  One Cat 5 cable from the Comms Tower to
          the  counter,  terminated  in  RJ45  sockets  at
          both ends and labelled “ CCTV “
       •  3No.  double  13A  S/S/O  above  the  ceiling
          adjacent to the menu screen bulkhead
       •  Three Cat 5 cable from the Menu screens to
          the  counter,  terminated  in  RJ45  sockets  at



       Scope of Works:      D
       •  To install 6 x internal day/night mini domes
          & 2 x external day/night/infra red cameras,
          controlled  by  a  8  way  1Tb  digital  recorder
          sited  in  the  managers  office  in  a  lockable
          box
       •  To  install  to  the  network  by  a  Netgear  (or
          similar and approved) router
















       4.4.6                       CCTV                                                  3 February 2016