          4.5.2 Cold Water                                      4.5.5 Best Practice Guidance
          •  Cold water installation shall commence from        The water supply is to be 25mm usually MDPE,
             the incoming mains stop-cock in the position       unless the site is contaminated and then barrier
             indicated on.                                      pipe would be required
          •  A double check valve to Water Regulations
             specification  shall  always  be  installed        Best Practice
             adjacent to the main incoming stop tap.            •  Lay  25mm  blue  MDPE  water  supply  pipe
          •  Cold  water  pipework  shall  be  run  in  light       from the store to the boundary at a minimum
             gauge  copper  tube  and  installed  as  the           depth of 750mm and a maximum depth of
             domestic hot water pipework.                           1300mm
          •  All pipework shall be insulated as the domestic    •  (If there is no private land then this must be
             hot water pipework with the addition of an             laid minimum 750mm below finished ground
             integral vapour barrier (Dunlop Armourflex/            level abutting the wall, coiled and capped)
             Foamflex or equivalent and approved).              •  Sufficient pipe must be available to enable
                                                                    this to reach the water main.  The highway
                                                                    end must be coiled and capped
                                                                •  To  duct  and insulated the  supply where  it
          4.5.3 Sink Waste                                          enters the building
          Problems  have arisen with  lack of  capacity         •  To fit a British Standard internal stop tap
          within the  drains from  the triple bowl sink. The
          main contractor  shall  size the pipework such
          that there is free flow of waste water when all
          three sink bowls are emptied at once, and so
          that if 2 bowls are emptied at once, there is no
          back flow into the third bowl.





          4.5.4 Thermostatic Blending Valve

          Where  a  thermostatic  blending  valve  is  fitted,
          i.e  for  the  knee  operated  whb,  etc,  this  MUST
          be  installed  not  more  than  2  metres  from  the
          appliance which it serves, to comply with water
          industry regulations.












          4.5.2 - 4.5.3 - 4.5.4 - 4.5.5  Cold Water, Sink Waster and Thermostatic Blending Valve  3 February 2016