Page 305 - (KU)01-75GAJ-1.5 - Change 1
P. 305

INTRO


   EP'S                                                              (KU)01-75GAJ-1.5                       FIGURES


                            Lost Bus Comm failure: If communications have failed, most ECBs stay
                            in their last state.                                                             ACAWS

                            D.  Potential Mission Impacts..................................................... Review
                                                                                                            GROUND
                                  ‡  Generator No. 1 will remain as-is; control not functional.


                                                           NOTE                                             TAKEOFF

                                   GEN 1 OFF (A) ACAWS only indicates switch position.
                                   Verify condition on system status page.                                  FIRE/SMK
  NORM                            ‡  0DQXDO  FRQWURO  RI  FDELQ  SUHVVXUL]DWLRQ  ZLOO  QRW  FORVH  RXWÀRZ

                                   valve; use other modes.                                                  PRES/OXY
                                    NOT FOR FLIGHT
                            E.  Fault Log.............................................................................. Review

                                 GEN 1, CAB PRESS CNTL B, GHC                                              ENG/PROP
                                 FIRE HNDL 1/2/3 FUEL/HYD/OIL, AV COOL FAN 1
                                 OUTFLOW VLV CLOSE, WIPERS, AUG STN LTS RELAY
                                 AUG CNI-MU 3, HDD 5                                                           FUEL
                                 BAU I #6
                                 AIL HI BOOST VLV
                                                                                                               AAR
                            (End of Procedure)

  SPEC                      1.10.5.4 ECBU 4 FAIL*                                                              ELEC


                            Condition:
                                                                                                               HYD
                            The ECBU has failed or lost bus communication with the MC.

                                                                                                            FLT CTRL
                           Q1  ARE MULTIPLE ACAWS DISPLAYED?

                                                                                                              GEAR
                              NO     Conventional failure: All ECBs lose power and multiple failures
                                     DUH HYLGHQW RQ WKH ÀLJKW GHFN  7KH $&$:6 DVVRFLDWHG ZLWK D
                             Lost    conventional failure are:                                              DOR/RMP
  PERF                       Bus       ‡   GEN 2 FAIL (C)
                             Comm
                             failure                                                                        JETTISON
                                       ‡   ICS FAIL (C)
                                       ‡   BAU II #1 FAIL* (C)

                                       ‡   R POD SUP VLV NOT OPEN (C)                                       LANDING
                                       ‡   CAB AUTO PRESS A FAIL (A)
                                       ‡   HF 1 FAIL (A)                                                    DITCHING
                                       ‡   R INTCON VLV NOT CLSD (A)
                                       ‡   R INTCON VLV NOT OPEN (A)                                        BAILOUT
                                       ‡   R POD SUP VLV NOT CLSD (A)

  OPER                               A.  GHC.............................................................. Select OVRD  FAULT LG

                            Use, copying and/or disclosure is   1 -265
                            governed by the statement on the
                            title page of this document.  BACK                                               CHARTS
   300   301   302   303   304   305   306   307   308   309   310