Page 56 - (KU)01-75GAJ-1.5 - Change 1
P. 56

INTRO


   EP'S                  (KU)01-75GAJ-1.5                                                             A     FIGURES


                                              1.2.2 CAUTIONS                                          B
                                                                                                             ACAWS
                                Alert/Condition                     Crew Action
                          FADEC 1A (2A, 3A or 4A) START FAULT                                         C     GROUND
                          Sensor(s) required to support   If the engine is running:
                          a successful start are faulty                                               D
                          or a main metering fuel valve   Continue operation.
                          fault has been detected. When   If the engine is shut down:                       TAKEOFF
                          a start is attempted, the other                                             E
                          FADEC takes control.           FADEC..................................... RESET   FIRE/SMK
  NORM                                                   A restart may be attempted. The              F
                                                         FADEC A FAIL (A) ACAWS may
                                                         appear during the start sequence, but
                                                         should disappear after the start.           G      PRES/OXY
                                    NOT FOR FLIGHT
                                                         If both FADEC A START FAULT (C)
                                                         ACAWS and FADEC B START FAULT                H    ENG/PROP
                                                         (C) ACAWS for the same engine are
                                                         displayed:
                                                                                                      I
                                                         Do not attempt a restart.                             FUEL
                                                         (QJLQH 6KXWGRZQ  ,Q ÀLJKW  SURFHGXUH
                                                         ........................................... Accomplish  L
                          FADEC 1B (2B, 3B, or 4B) START FAULT                                                 AAR
                          FADEC channel B P2, T2 or      If the engine is running:                   M
  SPEC                    Main Metering Valve (MMV)                                                            ELEC
                          sensor fault or MMC lane       Continue operation.
                          difference exists.             If the engine is shut down:                  N

                                                         FADEC..................................... RESET      HYD
                                                                                                     O
                                                         A restart may be attempted. The
                                                         FADEC B FAIL (A) ACAWS may                         FLT CTRL
                                                         appear during the start sequence, but        P
                                                         should disappear after the start.

                                                         If both FADEC A START FAULT (C)              R       GEAR
                                                         ACAWS and FADEC B START FAULT
                                                         (C) ACAWS for the same engine are
                                                         displayed:                                   S     DOR/RMP
  PERF                                                   Do not attempt a restart.

                                                         (QJLQH 6KXWGRZQ  ,Q ÀLJKW  SURFHGXUH         T     JETTISON
                                                         ........................................... Accomplish
                          FS A/C SHUTDOWN                                                             U
                          7KH ÀLJKW VWDWLRQ DLU          If a restart is desired after the auto             LANDING
                          conditioning pack is           shutdown of the air conditioner:
                          shutdown for water separator                                                V
                          RYHUSUHVVXUH DQG WKH ÀRZ       AIR COND FLT STA POWER........... On               DITCHING
                          control valve is closed.          Selecting a warmer temperature
                                                            may correct the problem.                 W
                                                                                                            BAILOUT