Page 636 - سابقة أعمال ايجي ريفيت السكني
P. 636

HVAC LEGEND:
                                         HIGH WALL SPLIT AIR CONDITIONER INDOOR UNIT
                                          AIR CONDITIONER OUTDOOR UNIT
                                       TR  TON REFREGATION
                                            SLEEVE
    ACU 09-OUT DOOR UNIT
                   HIGH WALL SPLIT DX
      ACU 01-OUT DOOR UNIT
                     HIGH WALL SPLIT DX
 ACU 06-OUT DOOR UNIT
                   HIGH WALL SPLIT DX
 ACU 12-OUT DOOR UNIT
                   HIGH WALL SPLIT DX  3" UPVC SLEEVE FROM FIRST FLOOR ( A.C.U.09)
      REFRIGIRANT PIPES/ELECTRIC CABLES
 9
 3" UPVC SLEEVE FROM FIRST FLOOR ( A.C.U.12)
     3" UPVC SLEEVE FROM GROUND FLOOR ( A.C.U.01)
 REFRIGIRANT PIPES/ELECTRIC CABLES   12  6  9  1  REFRIGIRANT PIPES/ELECTRIC CABLES
 3" UPVC SLEEVE FROM GROUND FLOOR ( A.C.U.06)    3" UPVC SLEEVE FROM GROUND FLOOR ( A.C.U.05)
  South Elevation
 REFRIGIRANT PIPES/ELECTRIC CABLES   5  REFRIGIRANT PIPES/ELECTRIC CABLES
 12
 6  ACU 05-OUT DOOR UNIT
                10  2
 ACU 13-OUT DOOR UNIT  1                    HIGH WALL SPLIT DX  ACU 10-OUT DOOR UNIT
                   HIGH WALL SPLIT DX                    HIGH WALL SPLIT DX  3" UPVC SLEEVE FROM GROUND FLOOR ( A.C.U.02)
 13  3" UPVC SLEEVE FROM FIRST  FLOOR ( A.C.U.13)    REFRIGIRANT PIPES/ELECTRIC CABLES
 ACU 16-OUT DOOR UNIT  13
 ACU 17-OUT DOOR UNIT  REFRIGIRANT PIPES/ELECTRIC CABLES   ACU 02-OUT DOOR UNIT
                   HIGH WALL SPLIT DX
                   HIGH WALL SPLIT DX                    HIGH WALL SPLIT DX  3" UPVC SLEEVE FROM FIRST FLOOR ( A.C.U.10)
                          REFRIGIRANT PIPES/ELECTRIC CABLES
 5
 17  16
 17  16  3
 3" UPVC SLEEVE FROM ROOF FLOOR ( A.C.U.17)    10  2
 TOP ROOF FLOOR
 REFRIGIRANT PIPES/ELECTRIC CABLES
 3" UPVC SLEEVE FROM GROUND FLOOR ( A.C.U.06)    3" UPVC SLEEVE FROM FIRST FLOOR ( A.C.U.16)    3  ACU 03-OUT DOOR UNIT  3" UPVC SLEEVE FROM GROUND FLOOR ( A.C.U.03)
 REFRIGIRANT PIPES/ELECTRIC CABLES   REFRIGIRANT PIPES/ELECTRIC CABLES                     HIGH WALL SPLIT DX  REFRIGIRANT PIPES/ELECTRIC CABLES
 6
 ACU 06-OUT DOOR UNIT
 6
                   HIGH WALL SPLIT DX
 7  ACU 07-OUT DOOR UNIT
 ACU18-OUT DOOR UNIT  18
 15                    HIGH WALL SPLIT DX
                   HIGH WALL SPLIT DX  18 14
 7
 3" UPVC SLEEVE FROM ROOF LOOR ( A.C.U.18)
 11
 REFRIGIRANT PIPES/ELECTRIC CABLES   14  ACU 11-OUT DOOR UNIT
 3" UPVC SLEEVE FROM FIRST FLOOR ( A.C.U.14)                      HIGH WALL SPLIT DX
 REFRIGIRANT PIPES/ELECTRIC CABLES   14  4
 3" UPVC SLEEVE FROM FIRST FLOOR ( A.C.U.15)
 ACU 14-OUT DOOR UNIT  11
 REFRIGIRANT PIPES/ELECTRIC CABLES
                   HIGH WALL SPLIT DX
                          3" UPVC SLEEVE FROM FIRST FLOOR ( A.C.U.11)
                           REFRIGIRANT PIPES/ELECTRIC CABLES
 ACU 15-OUT DOOR UNIT  3" UPVC SLEEVE FROM GROUND FLOOR ( A.C.U.07)
                   HIGH WALL SPLIT DX  4  REFRIGIRANT PIPES/ELECTRIC CABLES
          ACU04-OUT DOOR UNIT
                         HIGH WALL SPLIT DX
             3" UPVC SLEEVE FROM GROUND FLOOR ( A.C.U.04)
                                             A 3
              REFRIGIRANT PIPES/ELECTRIC CABLES
                                         M  0   0   7