Page 14 - Catalogue ANGLAIS 2016_Neat
P. 14

Pore Pressure cell model  EPZ

                                                                                 CHARACTERISTICS

                                                                                 Range of measurements:
                                                                                   0-300, 0-500, 0-1000, 0-2000,
                                                                                   0-3000, 0-5000 kPa

                                                                                 Accuracy :
                                                                                        -3
                                                                                   2 x 10   FS
                                                                                 Resolution :
                                                                                   2 x 10   FS
                                                                                        -4


                                                                                 Total length:
                                                                                   220 mm
                                                                                 Diameter:
             APPLICATIONS
             APPLICATIONS                                                          28 mm
             Pore  pressure  cell  model  EPZ  are  employed    in  the  relative
             measure  of  the  pressure  variation  of  the  present  water  in   Weight (Cordless) :
             every type of natural or reshaped geological materials.               700 g

             The  EPZ  is  a  capsule  of  aneroid  type,  what  means  that  there  is  a   Filter permeability :
                                                                                     -3
             partial space curved in the tight cell. The EPZ unit is mainly used in the   10  cm/s  (bronze)
                                                                                     -7
             follow-up  of  the  pore  pressure  in  soil  and  in  the  hydraulic  works   10  cm/s  (ceramic)
             (dams, dikes), grounds in which the presence of pressurized water or
             water in suction has a decisive impact  (landslides, alveoli of storage,
             elevations),  it  is  also  used  to  measure  the  water  level  in  piezometer
             device with a diameter lower than 40 mm.
             D                                                                   Cable :
             DESCRIPTIF ESCRIPTION
             The  cylindrical  parts  of  the  unit  EPZ  are  completely  manufactured  in   Model 2PBK
             bronze. Its elastic membrane insuring the transmission of the pressure   Individual shielding by pair
             to the wire and strong strength. The bronze has an excellent corrosion   Central Core in Kevlar
             resistance  and  in  the  outside  chemical  attacks.  (to  be  defined
             according to prescriptions and environment of use)
                                                                                 Resistance of coils :
             The  fluid  pressure  applies  inside  the  membrane  which  is  deforms   > 80 Ω
             under the variations of load and suction. The wire being fixed to the
             membrane,  sees  his  tension  varies  proportionally  to  the  small
             distortions  of  the  membrane,  that  is  to  say  also  in  the  change  of   Options :
             exercised  pressures.  A  calibration  for  every  sensor  is  realized  in   Adaptations for specific
             laboratory and allows to know and to deduct the pressure according to   installation
             the frequency of the measured signal.

             The choice of a filter with two separate sizes of pores (permeability of   Accessories:
             the ceramic or the sintered bronze) allows to modify this filter to the   Rotary switching box
             permeability of the ground in which the unit is installed.            Readout unit
             The  relation  between  the  frequencies  read  by  the  piano  wire  of  the
             unit EPZ allows to obtain directly and calculate the pressure by means
             of its coefficient K

             By design the cell integrates a mechanical thermal compensator of the

             Géo-Instrumentation - S.A.S. au capital de 37000 € - RCS Créteil B502768427 – APE : 7490B - N°TVA : FR10502768427