Electrical Piezometer model  NIVO


                                                                                 CHARACTERISTICS

                                                                                 Base of measure :
                                                                                   0-50cm to 0-30m of water

                                                                                 Accuracy :
                                                                                   < 0.3%  full scale

                                                                                 Resolution :
                                                                                   0.01% full scale

                                                                                 Total Length :
                                                                                   170.5 mm

                                                                                 Diameter :
                                                                                   21.4 mm
             APPLICATIONS PPLICATIONS
             A
             The  electric  piezometer  NIVO  is  specially  designed  for       Weight (without cable)
             the  measure  of  piezometric  levels    in  drillings  or  in        180 g
             reservoirs.
                                                                                 Using temperature :
             It is mainly used to monitor the works requiring a precise and
             continuous  recording  of  the  piezometry  which  surrounds  them      -10°  à +55°C
             (dams, dikes), and with grounds for which the monitoring of the     Exit signal :
             piezometers has a big importance.                                     4-20 mA
             D
             DESCRIPTIF ESCRIPTIF
             The  sensor  NIVO  is  made  with  a  piezoresistive  diaphragmic   Cable :
             element sensitive to the pressure, in a stainless envelope of big     1 ou 2 pairs
             robustness.                                                           Armed conductors separeted

             The  penetration  of  the  fluid  up  to  the  piezoresistif  element
             deforms it, what makes vary the resistance of the electric circuit
             of this element. The calibration of every sensor allows to know
             the pressure connected to the read measure.

             A stainless filter protects the piezometric room of the sensor of   Options :
             any intrusion for the measure.                                        Other measure range
             To simplify the measure while avoiding the calculations, the
             sensor is directly linked with an individual cable in laboratory,
             what allows a direct barometric compensation in the course of
             measure.                                                            Accessories :
             This  sensor  has  an  electric  exit  on  current  loop  4-20mA  (  2   Rotary switch box
                                                                                    Manual reading unit
             wires)  compatible  with  most  of  the  equipments  of  measure
             available on the market.


            Ce document n’est en aucun cas contractuel,   Géo-Instrumentation se réserve le droit de modifier ses produits et ses fiches techniques sans préavis


             Géo-Instrumentation - S.A.S. au capital de 37000 € - RCS Créteil B502768427 – APE : 7490B - N°TVA : FR10502768427