Page 209 - 2018_IFC
P. 209

MEANS OF EGRESS



         [BE] 1015.2 Where required. Guards shall be located along  3. For occupancies in Group R-3, and within individual
         open-sided walking surfaces, including  mezzanines, equip-  dwelling units in occupancies in Group R-2, where
         ment platforms,  aisles,  stairs,  ramps and  landings that are  the top of the guard serves as a handrail on the open
         located more than 30 inches (762 mm) measured vertically to  sides of stairs, the top of the guard shall be not less
         the floor or grade below at any point within 36 inches (914  than  34  inches (864  mm)  and not more than 38
         mm) horizontally to the edge of the open side. Guards shall  inches (965  mm)  measured vertically from  a line
         be adequate in strength and attachment in accordance with   connecting the leading edges of the treads.
         Section 1607.8 of the International Building Code.        4. The  guard height in assembly seating  areas shall
           Exception:  Guards are not required for the following     comply with Section 1029.17 as applicable.
           locations:                                              5. Along alternating tread devices and ships ladders,
              1. On the loading side of loading docks or piers.      guards where the top rail serves as a handrail shall
              2. On the audience side of stages and raised platforms,  have height not less than 30 inches (762 mm) and
                including stairs leading up to the stage and raised  not more than 34 inches (864 mm), measured verti-
                platforms.                                           cally from the leading edge of the device tread nos-
                                                                     ing.
              3. On raised stage and platform floor areas,  such as
                runways, ramps and side stages used for entertain-  6. In Group F occupancies where exit access stairways
                ment or presentations.                               serve fewer than three stories and such stairways are
                                                                     not open to the public,  and where the top  of the
              4. At  vertical openings in the performance  area of   guard also serves as a handrail, the top of the guard
                stages and platforms.
                                                                     shall be not less than 34 inches (864 mm) and not
              5. At elevated walking surfaces appurtenant to stages  more than 38 inches (965 mm) measured vertically
                and platforms for access to and utilization of special  from a line connecting the leading edges of the
                lighting or equipment.                               treads.
              6. Along vehicle service pits not accessible to the pub-  [BE] 1015.4 Opening limitations. Required guards shall not
                lic.                                          have openings that allow passage of a sphere 4 inches (102
              7. In assembly seating  areas at cross aisles in accor-  mm)  in diameter from  the walking surface to  the required
                dance with Section 1029.17.2.                 guard height.
           [BE] 1015.2.1 Glazing. Where glass is used to provide a  Exceptions:
           guard or as a portion of the guard system, the guard shall  1. From a height of 36 inches (914 mm) to 42 inches
           comply with Section 2407 of the  International Building   (1067 mm),  guards  shall  not have openings that
           Code. Where  the glazing provided  does not meet the      allow passage of a sphere 4 /  inches (111 mm) in
                                                                                             3
                                                                                              8
           strength and attachment requirements of Section 1607.8 of  diameter.
           the International Building Code, complying guards shall  2. The triangular openings at the open sides of a stair,
           be located along glazed sides of open-sided walking sur-  formed by the riser, tread and bottom rail shall not
           faces.
                                                                     allow passage  of a sphere 6 inches (152 mm) in
         [BE] 1015.3 Height. Required guards shall be not less than  diameter.
         42 inches (1067 mm) high, measured vertically as follows:
                                                                   3. At elevated walking surfaces for access to and use of
           1. From the adjacent walking surfaces.                    electrical, mechanical or plumbing  systems or
           2. On stairways and stepped aisles, from the line connect-  equipment,  guards  shall not have openings that
              ing the leading edges of the tread nosings.            allow  passage of a  sphere  21  inches (533 mm) in
                                                                     diameter.
           3. On ramps and ramped aisles, from the ramp surface at
              the guard.                                           4. In areas that are not open to the public within occu-
                                                                     pancies in Group I-3, F, H or S, and for alternating
           Exceptions:
                                                                     tread devices  and ships  ladders,  guards  shall not
              1. For occupancies in Group R-3 not more than three    have openings  that allow  passage of a sphere 21
                stories above grade in height and within individual  inches (533 mm) in diameter.
                dwelling units in  occupancies in Group R-2 not
                more than three stories above grade in height with  5. In assembly seating areas, guards required at the end
                separate means of egress, required guards shall be   of aisles in accordance with Section 1029.17.4 shall
                not less than 36 inches (914 mm) in height measured  not have openings that allow passage of a sphere 4
                vertically above the adjacent walking surfaces.      inches (102 mm) in diameter up to a height of 26
                                                                     inches (660 mm). From a height of 26 inches (660
              2. For occupancies in Group R-3, and within individual  mm) to  42  inches (1067 mm) above  the  adjacent
                dwelling units in occupancies in Group R-2, guards   walking surfaces,  guards shall not have openings
                on  the open sides of stairs shall have a height not  that allow passage of a sphere 8 inches (203 mm) in
                less than 34 inches (864  mm)  measured vertically   diameter.
                from a line  connecting the leading edges of  the
                treads.