Page 399 - Chief Architect Reference Manual
P. 399

Wall Specification Dialog



                               • If Slab Footing is checked, the Curb     offsets it towards the wall’s exterior. Not
                                  Width can be specified instead.         available if either Center Footing on Main
                                                                          Layer or Align Footing on Outside are
                                2   Check Footing to assign a concrete    checked.
                                    footing to the selected wall(s) and
                               enable the settings below. Only available   3  Specify how Monolithic Slab footings
                               when Foundation Wall is checked, above.     generate. These settings apply only
                               • Specify the Width and Height of the   when the selected wall defines the side of a
                                  footing below the selected foundation   Monolithic Slab. See “Foundations” on page
                                  wall(s). The Height value will be unavail-  687.
                                  able if the bottom height of the footing   • Specify the Chamfer Width and Height,
                                  has been edited. See “Stepped Founda-   which define the angled corners where the
                                  tions” on page 701.                     footing meets the underside of the slab.
                               • Check Automatic Footing Bottom        • Specify the Pour Number of the selected
                                  Height to restore the default height of the   Slab Footing. Pour Numbers are listed
                                  selected wall’s footing. Only available   separately in the Materials List. See “In
                                  when the footing bottom height has been   the Materials List” on page 695.
                                  edited.
                                                                        4  Check Sill Plate to reserve space for
                               • Check Vertical Footing to generate foot-  one or more sill plates, or mud sills
                                  ings that run up and down along any steps   between the selected foundation stem wall or
                                  in the foundation wall’s bottom height.   grade beam and the floor platform or framed

                               Offset - Specify how the footing is centered   wall that bears on it. Sill plates are generated
                               under the selected wall.                when the floor framing is generated. See
                                                                       “Sill Plates” on page 837.
                               • Check Center Footing on Main Layer to
                                  center the footing on the wall’s Main   •  Specify the Width and Height of the
                                  Layer. See “The Main Layer” on page     treated sill plates. If the Height is set to
                                  383.                                    zero, no sill plates are produced. Not
                                                                          available if Monolithic Slab is the
                               • Check Align Footing on Outside to align   selected Foundation Type.
                                  the footing along the wall’s exterior sur-
                                  face.  See “Wall Type Definitions” on   •  Specify the Count, which is the number
                                  page 383.                               of sill plates stacked vertically on each
                                                                          stem wall or grade beam.
                               • Specify the Footing Offset, which is the
                                  distance between the center of the footing   5  A preview of the selected wall,
                                  and the center of the wall. A value of 0   including any doors, windows, and/or
                                  centers the footing under the wall. A posi-  fireplaces inserted into it, displays on the
                                  tive value offsets the footing towards the   right. See “Dialog Preview Panes” on page
                                  wall’s interior surface. A negative value   42.







                                                                                                       399
   394   395   396   397   398   399   400   401   402   403   404