Page 397 - Chief Architect Reference Manual
P. 397

Wall Specification Dialog



                               • Check Extend Slope Downward to con-    4  Check Auto Roof Return to generate
                                  tinue a roof down over a bump out in an   roof returns on the selected wall. In
                                  exterior wall. See “Extend Slope Down-  most cases, roof returns only work for Full
                                  ward” on page 377.                   Gable Walls. See “Roof Returns” on page
                               • Check Roof Cuts Wall at Bottom to pre-  829.
                                  vent the portion of a selected wall located   • Specify the horizontal Length of the roof
                                  below an intersecting roof plane from   return in inches (mm).
                                  building.                            • Enter a value in inches (mm) to Extend
                               • Combine with Above Wall is only avail-   the roof returns past the overhang.
                                  able when a selected wall has an Attic   • Specify a Gable, Hip, or Full roof return.
                                  wall above it. Check this box to balloon
                                  frame the two walls when automatic   • Specify a Sloping or Flat roof return. See
                                  framing is built. The two walls remain   “Roof Tutorial” on page 439 of the User’s
                                  separate objects. See “Attic Walls” on   Guide.
                                  page 378.                            • Check the boxes to  Include Shadow
                                                                          Boards, Ridge Caps, Frieze molding,
                                2   Pitch Options - Specify the pitch or   and/or Gutters on the roof returns.
                                    pitches of the roof plane(s) above the
                               selected wall.                           5  Check Lower Wall Type if Split by
                               • Enter a value to define the Pitch of the   Butting Roof to specify the wall type
                                  roof plane bearing on the selected wall.   for any portion of the selected wall located
                                                                       beneath an adjacent, abutting roof plane,
                               • Check Upper Pitch to create a roof with   should one be present. A wall affected by this
                                  two pitches or, if the selected wall is a   setting is specified as a Pony Wall and the
                                  Full Gable Wall, a half hip condition.  upper wall is defined on the WALL TYPES
                               • Enter the Pitch of the second, upper roof.  panel. See “Exterior/Interior Pony Walls” on
                               • Specify the Height that the Upper Pitch   page 377.
                                  Starts at, or define the distance In from   A preview of the selected wall,
                                  Baseline that the second pitch begins. The   6  including any doors, windows, and/or
                                  two values are dynamic. Press the Tab key   fireplaces inserted into it, displays on the
                                  to update the relative numbers. These set-  right. See “Dialog Preview Panes” on page
                                  tings are also used to position a Dutch   42.
                                  Gable Wall.

                                3   Specify the Overhang Length, which       Additional  information  about  using  the
                                                                             settings on this panel can be found in
                                    is the horizontal distance from the
                                                                             the “Roof Tutorial” on page 439 of the
                               baseline to the eave. See “The Baseline” on   Reference Manual.
                               page 789.








                                                                                                       397
   392   393   394   395   396   397   398   399   400   401   402