Page 103 - FreesStyler® Installation and Startup
P. 103
®
INSTALLATION AND STARTUP
Chapter 5 Entrance and Exit Photo-Eyes
Entrance and Exit Photo-Eye General
There are two types of mounts available. The floor mounted and the wall mounted. Both styles are wired the same but they
have different variables to consider for positioning. DO NOT secure the Photo Eyes into place until you have read this
entire section.
Identification
Alignment
1) Point the Emitter directly at the Receiver
2) Point the Receiver directly at the Emitter
3) Finely adjust the position of the Receiver until “Indicator 4” of the Signal Strength
Light Bar is ON
Note: If Indicator 4 of the Signal Strength Light Bar can NOT be obtained, try
re-adjusting the Emitter and repeat step 3.
Working Temperature Range
• Non-Heated: 33° to 130° Fahrenheit
• Heated: -10° to 90° Fahrenheit
Note: If optional heat package has been installed, turn the power to the heat OFF before the
temperature exceeds 90° Fahrenheit. Turn it back ON before the temperature falls below
33° Fahrenheit.
1MANUL220 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 5-3