Page 104 - FreesStyler® Installation and Startup
P. 104

®
            INSTALLATION AND STARTUP


            Chapter 5 Entrance and Exit Photo-Eyes


            Entrance and Exit Photo-Eye General


               Modulation Frequency
                The standard configuration for Photo Eyes is to utilize Frequency A (shown in image
                to right), However if a system installation has the possibility for “Photo Eye Cross-
                Talk”, the affected Photo Eye set may be configured to utilize Frequency B. In this
                case both Emitter and Receiver must be wired for Frequency B.





                Receiver                                                                           Emitter
              33”
                                 If Wall Mounted configuration is used, mount the Photo Eyes at the heights indicated

                                                                                                        16”
                                                        End View

                                            Mount the Photo Eyes with a minimum of 6” off-set
                                                                                                Emitter
                Receiver                                                                               6”
                                                      Overhead View

               Wiring


                        Wiring for the Vector QS30       The diagram below was copied from the manual supplied from Banner(tm)
               Emitter
                          Brown       #340      24VDC
                           Blue      # 338       0VDC
                           Gray      # 340      24VDC

                           White   No Connection
               Receiver

                          Brown       #340      24VDC
                           Blue      # 338       0VDC

                           Gray      # 340      24VDC

                          White   FressStyler®  Input
                          Black   No Connection



















             5-4        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681       1MANUL220