Chapter 5 Entrance and Exit Photo-Eyes
Entrance and Exit Photo-Eye General
Modulation Frequency
The standard configuration for Photo Eyes is to utilize Frequency A (shown in image
to right), However if a system installation has the possibility for “Photo Eye Cross-
Talk”, the affected Photo Eye set may be configured to utilize Frequency B. In this
case both Emitter and Receiver must be wired for Frequency B.
Receiver Emitter
33”
If Wall Mounted configuration is used, mount the Photo Eyes at the heights indicated
16”
End View
Mount the Photo Eyes with a minimum of 6” off-set
Emitter
Receiver 6”
Overhead View
Wiring
Wiring for the Vector QS30 The diagram below was copied from the manual supplied from Banner(tm)
Emitter
Brown #340 24VDC
Blue # 338 0VDC
Gray # 340 24VDC
White No Connection
Receiver
Brown #340 24VDC
Blue # 338 0VDC
Gray # 340 24VDC
White FressStyler® Input
Black No Connection