Page 115 - FreesStyler® Installation and Startup
P. 115
®
INSTALLATION AND STARTUP
Chapter 6 Undercarriage
Undercarriage In-Ground Placement
The manifold is welded at a 5° angle and is to be pointed towards the exit of the bay.
Direction of Travel
Position the manifold with the center hole 5” towards the driver side of the doorway’s centerline.
Centerline of Doorway
Direction
of Travel 23” 5” 44”
9) Place the In-Ground Undercarriage Weldment Assembly in the correct location as shown below
and secure it to the floor using the supplied lag bolts.
Photo Eye
2”
Direction of Travel
Photo Eye
Between 2” and 20”
1MANUL220 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 6-3