Page 115 - FreesStyler® Installation and Startup
P. 115

®
                       INSTALLATION AND STARTUP


                       Chapter 6 Undercarriage


                       Undercarriage In-Ground Placement

                            The manifold is welded at a 5° angle and is to be pointed towards the exit of the bay.










                                                                                 Direction of Travel






                            Position the manifold with the center hole 5” towards the driver side of the doorway’s centerline.
                                                                     Centerline of Doorway


                           Direction
                           of Travel      23”                   5”                                 44”

                       9)  Place the In-Ground Undercarriage Weldment Assembly in the correct location as shown below
                          and secure it to the floor using the supplied lag bolts.
                                                                                                  Photo Eye



                                                                                               2”








                                                          Direction of Travel











                                                                                                     Photo Eye
                                                                             Between 2” and 20”











                        1MANUL220            Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681      6-3