            INSTALLATION AND STARTUP


            Chapter 6 Undercarriage


            Undercarriage In-Ground Connections

            10) Locate the supplied End Cap,  stainless steel Elbow  and  stainless steel Barbed Hose Fitting.
               Secure them to the manifold place as shown  below. Field supplied water hose  is  required  to
               connect the Barbed Hose Fitting  to  the  Plumbing Assembly. The Elbow and stainless steel
               Barbed Hose Fitting are to be placed on the side of the utilities.

                                                                                        Elbow and
                                                                                         Barbed
                   End Cap
                                                                                         Hose
                                                                                         Fitting

            11) Run  a  single  3/4” water feed from the 3/4" barbed hose fitting to the Undercarriage Valve
               Assembly as shown below.


                                         This pipe is field supplied
                     Undercarriage
                    Valve Assembly
                                            Shown with Rust Inhibitor Option

                                          Field supplied 3/4"
                                          water hose
                                                                      Plumbing Assembly   Plumbing Assembly
                                        Stainless steel                  (Standard)      (Rust Inhibitor)
                                        barbed hose fitting
                        Feed to Undercarriage
            12) Mount the supplied Undercarriage Valve Assembly to the wall in the appropriate
               location.
            13) Run water hose from the Barbed Hose  Fitting  to  the  Plumbing  Assembly  as
               shown.
            14) If you have the Rust Inhibitor option,  mount the supplied Chemical Pump
               Assembly to the wall in an appropriate location. Be sure to mount the Chemical   Chemical Pump
               Pump below the Chemical Injector as shown in the example below, to prevent air   Assembly (Rust
               bubbles in the line.                                                          Inhibitor)














                                               Injector
                                                                Chemical
                                                                  Pump



            15) Supply 110VAC feed to the Chemical Pump.