Page 25 - FreesStyler® Installation and Startup
P. 25

®
                       INSTALLATION AND STARTUP


                       Chapter 3 Getting Started


                       Installation Overview


                          Utility Requirements
                              Note:  See Conduit Electrical information page of system print set for full details.

                              The FreeStyler carwash should have a 2” water meter at 60PSI or 1-1/2” meter at 60PSI to
                              supply the entire system.  Below shows the individual connections from the water meter.

                              Note:  If your FressStyler® is supplied with less than 60PSI, a Booster Pump is
                                     recommended. The Booster pump specifications are stated below.

                                                     AMPS            Electrical                 Water

                                                     In FLA      Volts      Phase       Size    GPM        PSI
                            FressStyler®               30       208-240       3         3/4”      12       60
                                                       20         120         1

                            Wheel Cleaner              32       208-240       3        1-1/4”     30       30
                                                        2         120      1 on GFCI
                            Spot Free (RO)                                  1 (Two
                            *Sold Seperately          20 x 2      220       20AMP        1”       20       30
                                                                             feeds)
                            HydroBlade®                                                 3/4”
                            Undercarriage Options             SCC Controlled            3/4”      12       40
                            Bug Spray Applicator              SCC Controlled            3/4”      12       40

                            Booster Pump Maximum              SCC Controlled             1”       12    43 – Inlet
                                                                                                        65 – Boost
                            *Sold Seperately                                                            108 - System
                            On-Board Dryer             64         208          3
                                                       56         230          3
                                                       28         460          3
                            Air Cannon™ Dryer                      See supplied Air Cannon™ Dryer manual
                            AirBlade™ Dryer                         See supplied AirBlade™ Dryer manual
                            Air Compressor
                            *Sold Seperately           20       208-240        3       6 SCFM              110

                       See Local electrical codes for service factor amps.  Size load center and wires accordingly.




















                        1MANUL220           Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681      3-1