Installation
Installation of Applicators for ALL Systems
1) Locate and identify the two applicators shown below.
Primary Secondary
Applicator Applicator
The Primary Applicator has the tees mounted into the back and the Secondary
Applicator has a large and a small straight fitting on the back.
2) Using the “Layout Overview” shown earlier, mark out the floor of the tunnel for the Bell-
Hose Assembly.
3) The Primary Applicator should be positioned on the equipment room side. The
Secondary Applicator will be mounted on the opposite side of the bay. From the center-
line of the equipment the applicators should be mounted 61-1/4” to the back of the base
plate. This should set the nozzles around 112-1/2” apart
Note: In a drive-through configuration the applicators should not be mounted in the path of the
vehicles.
1MANUL089 Belanger, Inc. * PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 11