Page 15 - Free Standing CTA™
P. 15

FREE STANDING CTA

                       Installation


                       Installation of Applicators for ALL Systems


                              1)  Locate and identify the two applicators shown below.











                                                    Primary                      Secondary
                                                   Applicator                    Applicator



                                 The  Primary  Applicator  has  the  tees  mounted  into  the  back  and  the  Secondary
                                 Applicator has a large and a small straight fitting on the back.

                              2)  Using the “Layout Overview” shown earlier, mark out the floor of the tunnel for the Bell-
                                 Hose Assembly.

                              3)  The  Primary  Applicator  should  be  positioned  on  the  equipment  room  side.  The
                                 Secondary Applicator will be mounted on the opposite side of the bay. From the center-
                                 line of the equipment the applicators should be mounted 61-1/4” to the back of the base
                                 plate. This should set the nozzles around 112-1/2” apart

                              Note:   In a drive-through configuration the applicators should not be mounted in the path of the
                                     vehicles.






































                       1MANUL089          Belanger, Inc. * PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681      11