Page 10 - Kondor® KL 1 - E-1063 Programming and Operation Manual
P. 10

®
            KL1: 1063 PROGRAMMING AND OPERATION


            Chapter 1 Operator Interface/Standard User Screens


            User

                               E-1063                                Screen Key
                                                   ·  All Home: Homes the machine without a Reset
                                                   ·  Carriage Home: Homes the Carriage ONLY
                                                   ·  Force: Moves you to the Force screen
                                                   ·  Jog: Moves you to the Jog screen
                                                   ·  Monitor inputs: Moves you to the Monitor Inputs screen
                                                   ·  Monitor Outputs: Moves you to the Monitor Outputs screen
                                                   ·  About: Moves you to the About screen
                                                   ·  Carriage Find Limit: Causes the machine to locate the Entrance
                                                    and Exit limit
                                                   ·  Reset: Resets and Homes machine
                 The Machine MUST be in the Home position to perform a “Carriage Find Limit”.

                   Note:  The Carriage Find Limit must be performed on a machine that is a new install before any vehicles are
                          washed. This function typically does not need to be performed again after it has been completed once.

                 If pressing the reset button does not reset the machine, check the Fault screen for a reoccurring fault.
                User / Force
                             E-1063                    Screen Key
                                                Pressing the Force Enabled/Force
                                                Disabled toggle button alternates
                                                between the fields shown below:
                                                           /







                   To force an Application, fill  in the ovals next  to the desired Outputs. Enter the pump  speed, and then toggle
                   between “Force Enabled/Disabled”. The pump speed may be zero for some applications.

                   To turn off Force, press the “Force Enabled/Disabled” toggle button and clear all Forced ovals.
                User / Force / Ptrn
                             E-1063                    Screen Key
                                                Pressing the PTRN (Pattern) key
                                                moves you to this screen.
                         *                      Touching the E-1063 screen next
                                                to the Make Current button near
                                                the location marked by an asterisk
                                                (*) allows you to name that
                                                function.


                   Due to the flexibility of this system, dedicated FORCE applications are not provided. This screen consists of five
                   nameable FORCE patterns. To utilize a FORCE pattern, set a pattern on the FORCE screen. Next move to that
                   screen and press STORE PATTERN. Now you are to name the Pattern. To use the stored Pattern in the future,
                   press the MAKE CURRENT button.



             1-2              Belanger, Inc. ®* PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681                 1MANUL126