Page 41 - Kondor® KL 1 - E-1063 Programming and Operation Manual
P. 41
®
KL1: 1063 PROGRAMMING AND OPERATION
Chapter 5 Techniques in Programming
Typical Setup Examples
Example: The following is an example of a 2-Step Package that includes Triple Foam. This is one of many ways to
setup a package with these options.
The following is an example of an Entrance Operation running the Rocker Blaster. This Entrance Operation is utilizing a
25HP pump because the setting in the SETUP/ADVANCED CONFIGURATION is set to “ENTER PUMP VIA ENTER
OPERATION 1”
In this example the Rocker Blaster will turn on at 0.3 seconds after the vehicle has passed through the Entrance Door
Photo-Eyes.
It will turn off whenever the first OFF condition is true. The OFF conditions are as follows:
· 3 seconds after the vehicle has cleared the Entrance Door Photo-Eyes
· 0.1 seconds after the vehicle has arrived at the Wash Position and received a Stop Light
· After the Rocker Blaster has been ON for an elapsed time of 45 seconds
1MANUL126 Belanger, Inc. ®* PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 5-1