Page 41 - Kondor® KL 1 - E-1063 Programming and Operation Manual
P. 41

®
                      KL1: 1063 PROGRAMMING AND OPERATION


                      Chapter 5 Techniques in Programming


                      Typical Setup Examples

                          Example: The following is an example of a 2-Step Package that includes Triple Foam. This is one of many ways to
                          setup a package with these options.
















                          The following is an example of an Entrance Operation running the Rocker Blaster. This Entrance Operation is utilizing a
                          25HP pump because the setting in the SETUP/ADVANCED CONFIGURATION is set to “ENTER PUMP VIA ENTER
                          OPERATION 1”















                          In this example the Rocker Blaster will turn on at 0.3 seconds after the vehicle has passed through the Entrance Door
                          Photo-Eyes.

                          It will turn off whenever the first OFF condition is true. The OFF conditions are as follows:
                           ·   3 seconds after the vehicle has cleared the Entrance Door Photo-Eyes
                           ·   0.1 seconds after the vehicle has arrived at the Wash Position and received a Stop Light
                           ·   After the Rocker Blaster has been ON for an elapsed time of 45 seconds

























                       1MANUL126                 Belanger, Inc. ®* PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681                   5-1