Page 39 - Hydro-Hybrid™
P. 39
HYDRO HYBRID™
Nozzle Angle Adjustments
The overall angle of the middle manifolds spray pattern can be altered by slightly changing the
location of the brackets clamped to the legs.
Nozzle Movement
Default Bracket Position
The default position of the bracket is the exact length of the
connector arm. When the bracket is clamped in it’s default
position, the manifold spray pattern is centered at 90°.
Lowering Bracket Position
By slightly moving the clamp down 1” - 2”, the angle of the
spray pattern is downward.
This does NOT alter the stroke, only the angle.
Raising Bracket Position
By slightly moving the clamp up 1” - 2”, the angle of the
spray pattern is upward.
This does NOT alter the stroke, only the angle.
The same principals apply to the nozzles of the lower manifolds. Adjustment of the lower
manifolds nozzle angle will be covered in greater detail in the “Lower Manifold” section of this
document.
1MANUL253 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 37