Page 39 - Hydro-Hybrid™
P. 39

HYDRO HYBRID™


                       Nozzle Angle Adjustments

                       The overall angle of the middle manifolds spray  pattern  can  be altered by slightly changing the
                       location of the brackets clamped to the legs.


                       Nozzle Movement
                          Default Bracket Position



                                                     The default position of the bracket is the exact length of the
                                                     connector arm. When the bracket is clamped in it’s default
                                                     position, the manifold spray pattern is centered at 90°.





                          Lowering Bracket Position


                                                     By slightly moving the clamp down 1” - 2”, the angle of the
                                                     spray pattern is downward.
                                                     This does NOT alter the stroke, only the angle.




                          Raising Bracket Position


                                                     By slightly moving the clamp  up 1” - 2”, the angle of the
                                                     spray pattern is upward.
                                                     This does NOT alter the stroke, only the angle.




                           The same principals apply to the nozzles of the lower manifolds.  Adjustment of the lower
                           manifolds nozzle angle will be covered in greater detail in the “Lower Manifold” section of this
                           document.





















                        1MANUL253         Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681        37
   34   35   36   37   38   39   40   41   42   43   44