Page 191 - Saber® Installation & Startup
P. 191

INSTALLATION & STARTUP


                      Chapter 15 MixStir® Options


                      High Pressure Wax Option #2
                        9.  Locate the supplied 1/4” x 7 foot clear chemical feed and run from the barbed fitting on the E-gap Eductor
                           to the field supplied chemical drum making sure there is a siphoning filter on the end of the hose (in the
                           drum). You will have to remove this hose during the startup procedure after confirming chemical
                           dilution requirements.









                                    E-Gap
                                   Eductor

                        10.  Connect a city water feed to the main water inlet as shown below.








                                                  City Water Supply


                        11.  Connect the wax solenoid cable to the SDM Electrical Distribution Block as shown below.
                           SDM                             This image                 Dual plug feed for
                         Electrical
                       Distribution                        shown with the             Sealer Wax option
                           Block                           Low Pressure
                                                           (dual) plug. The
                                                           optional High                   SDM Electrical
                                                           Pressure (single)                Distribution
                                                                                              Block
                                                           plug will go here
                                                           in its place

                        12.  On the Output Board in the MCC, swap the wires for outputs 13 and 14.
                        13.  Program a Sealer Wax pass with a pump speed of 25% to run a low-pressure wax using the standard
                           Pulsatron™ pump.
                        14.  For a medium pressure (both arms), program the wax pass with a pump speed of 26-100%. This will use
                           the MixStir® high-pressure wax option and come out of both arms. For a high-pressure pass (1100 PSI,
                           one arm at a time), see “Application Configuration” in your Saber® Programming Manual. This will also
                           use the MixStir® High-Pressure Wax Option and come out of one arm at a time.
                           This type of pass is used often on an inexpensive base package, to apply presoak, and then rinse and
                           wax quickly.
                           In this configuration Drying Agent is using the MixStir® and the Sealer Wax is using an additional
                           Pulsatron™ pump.










                       1MANUL290       Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681   15-7
   186   187   188   189   190   191   192   193   194   195   196