Page 192 - Saber® Installation & Startup
P. 192
INSTALLATION & STARTUP
Chapter 15 MixStir® Options
High Pressure Wax Option #2
15. Connect the wax solenoid cable to the SDM Electrical Distribution Block as shown below.
SDM This image Dual plug feed for
Electrical
Distribution shown with the Sealer Wax option
Block Low Pressure
(dual) plug. The
optional High SDM Electrical
Pressure (single) Distribution
plug will go here Block
in its place
16. On the Output Board in the MCC, swap the wires for outputs 13 and 14.
17. Program a Sealer Wax pass with a pump speed of 25% to run a low-pressure wax using the standard
Pulsatron™ pump.
18. For a medium pressure (both arms), program the wax pass with a pump speed of 26-100%. This will use
the MixStir® high-pressure wax option and come out of both arms. For a high-pressure pass (1100 PSI,
one arm at a time), see “Application Configuration” in your Saber® Programming Manual. This will also
use the MixStir® High-Pressure Wax Option and come out of one arm at a time.
This type of pass is used often on an inexpensive base package, to apply presoak, and then rinse and
wax quickly.
In this configuration Drying Agent is using the MixStir® and the Sealer Wax is using an additional
Pulsatron™ pump.
15-8 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL290