Page 38 - Saber® Installation & Startup
P. 38
INSTALLATION & STARTUP
Chapter 3 Getting Started
Fastening Needs and Other Required Materials
Due to the variables from site to site (wall thickness, wall type, slab heat, weld plates, etc.)
Belanger, Inc. has no way to anticipate your Saber® fastening needs. Below is a
recommendation of fastener types and quantities required for installation. All the fasteners listed
are typically available at an Industrial or Commercial supplier, or can be purchased through the
Belanger Aftermarket group.
Note: Please be aware that the typical “home do-it-all” stores rarely carry stainless steel and/or
heavy grade fasteners, therefore you should plan accordingly.
· The Saber® Floor Mounted system is designed to be secured with 5/8” lag bolts.
· The Wall Mounted system is designed to be secured to the wall using 1/2” diameter stainless
steel threaded rod.
· The Floor Mounted Dryer is designed to be secured with 5/8” lag bolts.
Note: Hydraulic hoses are rated by “bend radius” and “PSI”, however this document uses PSI to
rate hoses.
Other field supplied items that will be required, depending on the level of your installation,
include; water hose, poly-flow tubing, hydraulic hose assemblies and other plumbing lines. All of
these items are also typically available at an Industrial or Commercial supplier, or can be
purchased through the Belanger Aftermarket group.
Base Saber®
Floor Mounted Frame
5/8” anchors (16) 4 holes each leg
Wall Mounted Frame
1/2” anchors Or (16) 4 holes each wall mount assembly
stainless steel threaded rod
Carriage and Boom Assembly
1/2” threaded rod (4 holes) to mount boom support
Thru-wall Plate Kit
3/4” hydraulic hose (1) from Thru-Wall Plate to Boom; 2000 PSI or greater minimum rating
(1) from Wall Manifold to Thru-Wall Plate; 2000 PSI or greater minimum rating
1” hydraulic hose (1) from Wall Manifold to Pumping station; 2000 PSI or greater minimum rating
1/2” anchors Or threaded rod (4 holes) to mount Thru-Wall Plate
Pump Station
3/4” hydraulic hose (1) to Rocker Blaster/Undercarriage; 2000 PSI or greater minimum rating
1” hydraulic hose (1) to Wall Manifold; 2000 PSI or greater minimum rating
3/4” water hose (1) to SDM; from low pressure deselect on the side of the Pumping Station
1” water hose (1) from hot water tank overflow to drain
(1) from cold water tank overflow to drain
1” FNPT fitting (1) from ball valve at the main water feed to the hot and cold tank main feeds