Page 45 - DuraTrans XD® Conveyor
P. 45

DURATRANS XD® CONVEYOR



                      Installation


                      Optional Reversing Valve

                          Assembly
                             1)  Secure the valve in a convenient location down in the conveyor trench (example shown
                                 below).
                                              Three possible mounting locations
                                                         (Valves Not to Scale)




















                             2)  Remove and discard the caps and using two short hydraulic hoses (located in the
                                 Conveyor Accessory Box), connect all hydraulic hoses as shown below.



                          Return line going to

                         Hydraulic Filter/Tank                                 Cap
                        Outgoing line going to
                             Conveyor Motor
                                                                               Outgoing line going to
                                                                               Conveyor Motor
                                   Cap













                                Pressure line from
                                Hydraulic Pump/Flow
                                Control Valve on Conveyor




                      1MANUL010           Belanger, Inc.® * PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681     41