Page 45 - DuraTrans XD® Conveyor
P. 45
DURATRANS XD® CONVEYOR
Installation
Optional Reversing Valve
Assembly
1) Secure the valve in a convenient location down in the conveyor trench (example shown
below).
Three possible mounting locations
(Valves Not to Scale)
2) Remove and discard the caps and using two short hydraulic hoses (located in the
Conveyor Accessory Box), connect all hydraulic hoses as shown below.
Return line going to
Hydraulic Filter/Tank Cap
Outgoing line going to
Conveyor Motor
Outgoing line going to
Conveyor Motor
Cap
Pressure line from
Hydraulic Pump/Flow
Control Valve on Conveyor
1MANUL010 Belanger, Inc.® * PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 41