Page 40 - DuraTrans XD® Conveyor
P. 40
DURATRANS XD® CONVEYOR
Installation
Installing the Plastic Guide Rail
Helpful Hint
The following procedure requires field fabrication
1) Locate the supplied Guide Rail FIXTURE CLAMP (part #102941) as shown below.
2) Slide the plastic guide rail onto the guide rail angle starting with a 10 FT section at the
entrance.
5 foot Center Section shown above
Note: This section will cover the 5 FT entrance and 5 FT of the next section. As you have a 5 FT
center section installed, the plastic has to be cut down to 7 foot 6 inches. This will cover the
exit end of the previous section and half or 2 foot 6 inches of that 5 FT section.
36 Belanger, Inc®. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL010