DURATRANS XD® CONVEYOR
Installation
Utility Connections
Electrical Connections
Electric Drive Motor/Gearbox
Drive Motor: Wire the drive motor to the VFD per the supplied DuraTrans electrical drive wiring schematic.
Note: Delta is low voltage and Wye is high voltage.
Air-Panel
Belanger® Conveyor Controller:
#1 lead to terminal#338
#3 lead to PLC Input
Main air supply Other: In series with Hydraulic Low-
90-PSI minimum Level or in series with E-Stop
120-PSI maximum circuit
NOTE: MUST HAVE LESS THAT A
5AMP DRAW
110VAC in from DCC or field
supplied Roller-Up control unit
Proximity Sensors
This proximity switch 1ELECT-SN360 is a very versatile sensor depending on how it’s wired it will either sink (NPN)
N/O or N/C or source (PNP) N/O or N/C.
Belanger® DuraTrans XD® with a Belanger® DCC controller
Roller Count Proximity Sensor Source N/C Black Wire +24DC #222
(Belanger® Conveyor Controller) White Wire - Load # 11 on the Input Board
Pulse Proximity Sensor Source N/O White Wire +24DC #222
(Belanger® Conveyor Controller) Black Wire Load #6 on the Input Board
Roller Count Proximity Sensor Sink N/C White Wire OVDC
Black Wire – Load (PLC Input)
Pulse Proximity Sensor Sink N/O Black Wire OVDC
White Wire - Load (PLC Input)
Roller Count Proximity Sensor Pulse Counting Proximity Sensor