DURATRANS XD® CONVEYOR



            Installation


            Pneumatic Air Panel

               The Air-Panel has an Inlet Filter that feeds the first Regulator for the Roller-Up Cylinder (set
               between 70PSI – 80PSI). The regulated air then feeds the 4-way electric valve.

               Two 1/4” airline runs from the 4-Way valve to the Roller-Up Cylinder (located on the entrance
               conveyor section).

               The regulated air runs through flow-controls that are installed into the ports on the Roller-Up
               Cylinder. The flow-controls on the Cylinder will control the Cylinder speeds.
               The second Regulator is for the Tension Cylinder (set between 70PSI – 80PSI). This regulated air
               then feeds the 4-way manual valve. This valve has an outgoing port to the Tension Cylinder where
               there is a brass tee installed along with a pressure switch which is pre-set at 50PSI.

                      The pressure switch will insure that if the chain has less than 50PSI the conveyor will not
                      run.
                      The pressure switch MUST be wired into the “Low Air Fault” on the Belanger® Conveyor
                      Controller System or in series with the E-Stop circuit using wires #1 and #3 from the
                      pressure switch (normally open).
               Locate  the  supplied  Pneumatic  Air  Panel  and  mount  it  to  the  wall  in  dry  a  location  that  will
               accommodate your airlines and is conveniently accessible.























                       Main air supply
                       90-PSI minimum
                       120-PSI maximum