DURATRANS XD® CONVEYOR
Installation
Pneumatic Air Panel
The Air-Panel has an Inlet Filter that feeds the first Regulator for the Roller-Up Cylinder (set
between 70PSI – 80PSI). The regulated air then feeds the 4-way electric valve.
Two 1/4” airline runs from the 4-Way valve to the Roller-Up Cylinder (located on the entrance
conveyor section).
The regulated air runs through flow-controls that are installed into the ports on the Roller-Up
Cylinder. The flow-controls on the Cylinder will control the Cylinder speeds.
The second Regulator is for the Tension Cylinder (set between 70PSI – 80PSI). This regulated air
then feeds the 4-way manual valve. This valve has an outgoing port to the Tension Cylinder where
there is a brass tee installed along with a pressure switch which is pre-set at 50PSI.
The pressure switch will insure that if the chain has less than 50PSI the conveyor will not
run.
The pressure switch MUST be wired into the “Low Air Fault” on the Belanger® Conveyor
Controller System or in series with the E-Stop circuit using wires #1 and #3 from the
pressure switch (normally open).
Locate the supplied Pneumatic Air Panel and mount it to the wall in dry a location that will
accommodate your airlines and is conveniently accessible.
Main air supply
90-PSI minimum
120-PSI maximum