Page 13 - Jet Pumping Station
P. 13

JET PUMPING STATION


                    Installation


                    Assembly

                           4)  Level the machine by adjusting the built in leveling feet. This has direct bearing  on  float  valve
                               performance.



                                                                        Step 2:
                                                                        tighten these nuts





                                     Step 1:
                             raise or lower this nut
                                                                       Horizontal leg
                                      Leveling foot                    (near the floor)
                                         (typical)

                           5)  Install the inlet plumbing to float valve. A shut off valve should be installed in this feed line (supplied by
                               customer). In addition, a connection to the float valve inlet (3/4” FNPT) should be made with flexible
                               hose.

                                         Main water feed            3/4” flexible hose required
                                         (typically 2”)             (supplied by customer)

                                        Recommended 1”, minimum 3/4” copper
                                           (copper, supplied by customer)







                                                                                        Float valve
                                                            Recommended 3/4” barbed
                                                                hose fittings
                                     Reducer                 (supplied by customer)
                                     (supplied by customer)
                                                                     Float valve inlet assembly
                                                 Shut off valve               3/4” FNPT    Outlet
                                           (supplied by customer)                       plumbing to
                                                                                            tank








                           Note:  Fluid inlet, minimum 3/4” feed to float valve.