Page 13 - TopWinder®
P. 13

®
                                         ®
                       TopWinder


                       Specifications


                       Requirements
                          Physical
                              Tunnel space required    118-1/2”

                              Unit height             133”
                              Unit width              150-7/8”

                          Utility
                              Electrical              3 phase, 60Hz Motor: 1HP STDV or 1HP 575V
                                                      110V for Retract Option
                              Pneumatic
                                                      .3 CFM @ 90 PSI minimum 120 PSI maximum
                              Water                   (1) 3/4” hose @ 4 GPM @ 40 PSI
                              Hydraulic               4 GPM @ 900 PSI


                       Output
                          Physical
                              Vehicle clearance, height    90”





                                 DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE SERVICING ANY
                                                                EQUIPMENT!

                                                            CAUTION


                                      Always wear safety glasses when performing maintenance on any equipment.

                                                            CAUTION


                              It is recommended that a licensed electrician is contracted to perform all electrical installations.

                                YOUR HYDRAULIC SYSTEM MUST BE CAPABLE OF ADJUSTMENT TO 116 RPM AT
                                 900 PSI (62.1 BAR) WHILE LOADED AGAINST VEHICLE. PLEASE VERIFY YOUR
                                SYSTEMS CAPABILITY TO MEET THESE SETTING WHILE RUNNING A VEHICLE
                                                PRIOR TO INSTALLING PIECE OF EQUIPMENT

                                  A compressed Air System should be set correctly to support 90 PSI necessary to operate
                               equipment, but should never be set to deliver more than 120 PSI air pressure to the Belanger®
                                                              specified equipment.














                       1MANUL755            Belanger, Inc.® * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681        9
   8   9   10   11   12   13   14   15   16   17   18