Page 13 - Gyro Wrap™ Signature ® Series
P. 13
GYRO WRAP™ Signature ® Series
Specifications
Requirements
Physical
Tunnel space required Unit Length: entrance side of the base plate to the outermost tip of
Neo-Tex on the passenger side wheel – 129-1/2
Unit width 151-1/2”: outside to outside of base plates
Unit height 120”: from the floor to the top of the plastic motor cover
Vehicle height clearance 90”
Utility
Electrical 1 HP; 208-230/460 V; 60 Hz
1 HP; 575 V; 60 Hz
2 HP; 208-230/460 V; 50 Hz
Pneumatic 0.3 CFM @ 90-120 PSI maximum
Water 2.8 GPM total or 1.4 GPM per side @ 40 PSI
DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE SERVICING ANY
EQUIPMENT!
Always wear safety glasses when performing maintenance on any equipment
It is recommended that a licensed electrician is contracted to perform all electrical installations.
YOUR HYDRAULIC SYSTEM MUST BE CAPABLE OF ADJUSTMENT TO 76 RPM AT 900
PSI (62.1 BAR) WHILE LOADED AGAINST VEHICLE. PLEASE VERIFY YOUR SYSTEMS
CAPABILITY TO MEET THESE SETTING WHILE RUNNING A VEHICLE PRIOR TO
INSTALLING PIECE OF EQUIPMENT
A compressed Air System should be set correctly to support 90 PSI necessary to operate
equipment, but should never be set to deliver more than 120 PSI air pressure to the Belanger
specified equipment.
1MANUL248 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 9