Page 37 - QuickFire® Wrap Around Signature® Series
P. 37
QUICKFIRE® Signature ® Series
Installation
Installing Cleaning Material
Upper Hub: Neo-Tex®
Fill every third slot
Hub Overhead View
24 (25” x 8” x 1/8” thick)
Pieces of Neo-Tex® , 2
per clip
12 Wash Clips
7) Locate 12 of the 25” x 8” x 1/4” thick Neo-Tex® pieces and twelve 8” Wash Clips.
8) Place the Wash Clips ends through the holes of the packs.
9) Fill every third “C” Channel slot as shown below (12 pieces in all). Make sure the Packs are
pushed down as far as possible. Be sure the flaps are in the right direction.
12 (25” x 8” x 1/4” thick)
Hub Overhead View Fill every third slot Pieces of Neo-Tex® , 1
per clip
12 Wash Clips
1MANUL826 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 33