Page 54 - QuickFire® Wrap Around Signature® Series
P. 54

QUICKFIRE® Signature ® Series


             Operational Performance and Controls


             Overview of Controls

                 OUTSIDE Swing-Flow Control: When the QuickFire® Wrap is   1RGLTR175 Regulator: The function of this Regulator
                 at rest, the wheels set in the path of the vehicle. Adjusting the   controls the inward pressure applied to the vehicles front, side
                 “Outside Swing Flow Controls” alters resistance as the vehicle   and rear. This pressure is also termed “cloth penetration”.
                           moves the wheels out of the way.













                Exhaust Flow Control (Limit Switch): This is a “Valve” used to   INSIDE Swing-Flow Control: When the QuickFire® Wrap is
                 control the speed of the head retract. Change to the “state” of   moving down the side of the vehicle and reaches the rear end,
                 the Sizer Limit Switches initiates movement. When the wheels   the forces of the wheels moving inward to make contact with
                 are traveling up the side of the vehicle, the Head is also moving   the rear are adjusted by altering the “I Swing Flow Controls” set
                 down the rails of the Boom. The travel speed of the Head can   in the path of the vehicle. Adjusting the “Outside Swing Flow
                 be adjusted by turning the Needle Valves on the Limit Switch.   Controls” alters resistance as the vehicle moves the wheels out
                                                                              of the way.













                       AIR QUICK-DUMP and BACK CLEANING: .         AIR QUICK-DUMP and BACK CLEANING: .





























              50          Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681           1MANUL826
   49   50   51   52   53   54   55   56   57   58   59