             Trouble Shooting

                         Problem                                   Solution
                                            •   Check for missing pieces or damaged cleaning material
                 Wobbling Boom or Shaft
                                            •   Check Bearings for wear
                                            •   Check for bent shaft
                                            •   Check shock for leaking oil, loose bolts or worn out rubber mount
                                                grommet

                 Brush is turning too slow   •   Confirm flow control setting is all the way open
                                            •   Confirm hydraulic unit has 1000 – 1100 PSI
                                            •   Replace motor on hydraulic unit

                 Electric drive: Wheel Speed   •   Check motor starter
                                            •   Check gearbox
                                            •   Check motor