Page 43 - H2AIR® Arch
P. 43
®
H2AIR ARCH
Maintenance
Trouble Shooting
Problem Cause Solution
Top Flip: No power Check power coming to Air Panel
Not Rotating Controller program Verify that the Controller has been programmed
Air pressure properly
Cylinder airline connections Check that air pressure on Air Panel has been
set properly
Check airlines connections at the Air Panel and
the Top Flip Cylinder
Top Flip: Incorrect air pressure Adjust the extend and retract air pressure on the
Rotation Speed Air Panel and/or
Adjust the flow control valves on the extend and
retract ports on the Top Flip Cylinder to obtain
the desired rotation speed
Dryers: No power Check power coming to Motors
Not Working Incorrect wire connections Check to make sure the wire connections are
Controller program correct in the Motor Electrical Box
Verify that the Controller has been programmed
properly
Dryers: Controller program Verify that the Controller has been programmed
Turning On Late or to turn on and off the dryers at the desired times
Turning Off Early
Airis®: No power Check power coming to Air Panel
Not Opening Controller program Verify that the Controller has been programmed
properly
Cylinder airline connections
Check that air pressure on Air Panel has been
set properly
Check airlines connections at the Air Panel and
the Airis® Cylinders
Airis®: * Air pressure settings Adjust the extend and retract air pressure on the
Opening & Closing Speed Air Panel and/or
Adjust the flow control valves on the extend and
retract ports on the Airis® Cylinders to obtain the
opening and closing speeds
Spray Manifolds: Controller program Verify that the Controller has been programmed
Not Spraying or to turn water on at the desired time
Poor Rinse on Vehicle Verify Spray Nozzles are aligned properly
Spray Manifolds: Nozzles clogged Remove Spray Nozzles and clean with thin wire
Pulsating or Kink in hose Check all fittings on complete system to assure
Weak Spray Inadequate water pressure they are tight and do not leak
Remove any kinks from hose
Open water valve to fullest
Call Distributor for advice on installing booster
pump
LED Lights: No power Check electrical connections in Electrical Boxes
Not Turning On Incorrect wire connections Check Main Power connections
Controller program Verify that the Controller has been programmed
properly
Short in LED light assembly
Replace LED light assembly
LED Lights: Controller program Verify that the Controller has been programmed
Not Turning Off properly