               Initial Startup Procedures

               Install Spray Nozzles & Verify Proper Function of Top Assembly and Airis®
                  10) The H2AIR® Arch has several functions that must be activated as a vehicle approaches the arch.
                      Program the H2AIR® Arch so that when the front bumper of a vehicle is about 2 feet from the
                      H2AIR® Arch the following functions start simultaneously:
                          Turn on Water for the Top and Leg Manifolds
                          Turn on Air Cannon™ DryLite™ Dryers
                          Activate the Airis® 4-way valve to open the Airis® Assemblies
                          Turn on the LED Lights in the Leg Assemblies, Top Manifolds and Dryer Housings

                      Note:  It is recommeded that the Airis® Assemblies open as quick as possible after the dryers turn on.
                             Use  the  Flow  Control  on  the  Extend  Ports  of  the  Airis®  Cylinders  to  increase  the  speed  at
                             which the Airis® Assemblies open.
                  11) Run  a  test  wash  on  a  vehicle  to  confirm  the  H2AIR®  Arch  is  operating  as  desired  and  make
                      adjustments as necessary.