Page 39 - H2AIR® Arch
P. 39
®
H2AIR ARCH
Initial Startup Procedures
Install Spray Nozzles & Verify Proper Function of Top Assembly and Airis®
5) In each Top Manifold Assembly install four (4) of the supplied Spray Nozzles into the Check
Bodies, refer to the image below.
Note: Lubricate the Nozzle threads with a Liquid-Teflon™ for easier installation and maintenance.
Top Manifold (2) Check Bodies
Four (4) per Top Manifold
Apply Liquid Teflon™ to the Spray Nozzle
Nozzle Threads at Installation Four (4) Nozzles per Manifold
Eight (8) Nozzles in Top Assembly
6) Rotate each Spray Nozzle so it is installed at a 5° angle to the centerline of the Manifold. Be sure
to rotate all of the nozzles in the same direction, see the image below.
5°
Centerline of
Manifold
1MANUL958 Belanger®, Inc. *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 35