Page 35 - H2AIR® Arch
P. 35
®
H2AIR ARCH
Utilities
Air Connections: Air Panel to H2AIR® Top Flip Cylinder
1) Run a field supplied 1/4” poly-flow airline from the Main Air Supply to the Main Air Connection on
the Air Panel. See the image below.
Extend Regulator Connection
Retract Regulator Connection 1/4” Poly-Flow Tube to the
1/4” Poly-Flow Tube to the Retract Extend Port on the Cylinder
Port on the Cylinder
4-Way Air Valve
120 VAC Output from
the Site Controller
Main Air Connection
1/4” Poly-Flow Tube
2) Run a field supplied 1/4” poly-flow airline from the extend regulator on the Air Panel to the extend
port on the Top Flip Cylinder. See the images above and below.
Field Supplied
1/4" Poly Flow Tube
Route as necessary
Retract Port
Extend Port
Notes:
Each port on the Cylinder
has a flow control valve to
adjust the cylinder actuation Extend Port
speed. Air Panel
The Cover was removed
from the Top Flip to see the Retract Port
ports on the Cylinder.
Field Supplied 1/4" Poly
Flow Tube from the
Main Pneumatic Source
@100 psi Air Flow Min.
3) Run a field supplied 1/4” poly-flow airline from the retract regulator on the Air Panel to the retract
port on the Top Flip Cylinder. See the images above.