                Air Connections: Air Panel to Airis® Assemblies
                    1)  Route a field supplied 1/4" poly-flow airline from the Main Air supply and connect it to the Main
                        Feed Port located on the bottom of the Air Panel Valve.


                                                    3/8” Extend & Retract Ports















                                             Air Panel: 111389

                                                              1/4”  Main      Valve
                                                              Feed Port
                    2)  Run two field supplied 3/8” poly-flow airlines from the ports on top of the Air Panel Valve out to
                        the Air Cannons™ these lines will be used to control the Airis® Cylinders, refer to Note below.
                        Designate one of the airlines as Cylinder Extend and one as Cylinder Retract.
                    3)  In the Airis® accessory box locate the two Union-Y Unequal 3/8”T x 1/4"T Fittings (1UNION-
                        PL690). Install the Union-Y Fittings into each of the 3/8” poly-flow airlines that have been routed
                        to the wash bay.
                    4)  Connect two 1/4" poly-flow airlines to the Union-Y Fitting on the extend airline. Route an airline to
                        each Air Cannon™ and connect them to the extend ports on the Airis® Cylinders.



                                                                   Note:  For best results, run the 3/8” airlines as close
                                     Extend Port
                                                                          to  the  Air  Cannons™  as  possible  before
                                     Extend Flow Control Valve            reducing to the 1/4" airlines with the unions.
                                     Airis® Cylinder
                                                                   Note:  Make sure that the 1/4" airlines are equal in
                                                                          length to each Airis® cylinder this will ensure
                                     Retract Port                         that the Airis® assemblies will react similar in
                                     Retract Flow Control Valve           speed.


                                         Airis® Assembly
                                                                   Note:  The rate at which the Airis® Assemblies open
                                                                          and  close  can  be  controlled  by  adjusting  the
                                                                          Flow  Controls  on  the  Airis®  Cylinder’s
                                                                          Extend and Retract Ports.

                    5)  Connect two 1/4" poly-flow airlines to the Union-Y Fitting on the retract airline. Route an airline to
                        each Air Cannon™ and connect them to the retract port on the Airis® Cylinders.
                    6)  Use the Controller to turn on the Airis® Assemblies to confirm they are operating properly.
                    7)  Adjust the flow controls on each Cylinder to achieve the desired opening and closing speed of the