Page 31 - DuraJet™ / AlumaJet™ Arches
P. 31

DURAJET™ ARCH


                      Maintenance


                      Routine Procedures

                          DuraJet™ or AlumaJet™ Arch (Daily)
                          ·   Visually check the spray of each of the nozzles.
                             ·   Clean or replace as necessary.
                          ·   Visually inspect all hoses and airlines for damage or wear.
                             ·   Replace as necessary.
                          ·   Inspect the arch for clogged nozzles. This can best be done while running a test vehicle at
                              the start of the business day.
                             ·   Insert a thin wire into the nozzle opening to clear any obstructions. Sometimes simply tapping on the nozzle can clear it.
                          ·   Run a test wash

                          DuraJet™ or AlumaJet™ Arch (Monthly)
                          ·   Wash component down with a good degrimer such as Tide laundry detergent and hot water.


                      Trouble Shooting

                             Problem                 Cause                            Solution
                         Pulsating or weak   ·   Nozzles clogged       ·   Remove from arch manifold and clean with thin wire
                         spray             ·   Dirt in solenoid valve   ·   Disassemble and clean solenoid valve

                                           ·   Kink in hose            ·   Remove any kinks from hose
                                           ·   Inadequate water pressure   ·   Open water valve to fullest
                                                                       ·   Call Distributor for advice on installing booster pump





































                       1MANUL028          Belanger®, Inc. *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681     27