Page 31 - DuraJet™ / AlumaJet™ Arches
P. 31
DURAJET™ ARCH
Maintenance
Routine Procedures
DuraJet™ or AlumaJet™ Arch (Daily)
· Visually check the spray of each of the nozzles.
· Clean or replace as necessary.
· Visually inspect all hoses and airlines for damage or wear.
· Replace as necessary.
· Inspect the arch for clogged nozzles. This can best be done while running a test vehicle at
the start of the business day.
· Insert a thin wire into the nozzle opening to clear any obstructions. Sometimes simply tapping on the nozzle can clear it.
· Run a test wash
DuraJet™ or AlumaJet™ Arch (Monthly)
· Wash component down with a good degrimer such as Tide laundry detergent and hot water.
Trouble Shooting
Problem Cause Solution
Pulsating or weak · Nozzles clogged · Remove from arch manifold and clean with thin wire
spray · Dirt in solenoid valve · Disassemble and clean solenoid valve
· Kink in hose · Remove any kinks from hose
· Inadequate water pressure · Open water valve to fullest
· Call Distributor for advice on installing booster pump
1MANUL028 Belanger®, Inc. *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 27