Page 30 - DuraJet™ / AlumaJet™ Arches
P. 30
DURAJET™ ARCH
Installation
Initial Start Up
3) Verify that the UPPER CHANNEL ASSEMBLY ROTATES correctly.
Verify that the Upper Channel assembly rotates 30° from center toward the entrance of
the wash and 30° from center toward the exit of the wash. See the image below.
Upper Channel Assembly
Nozzle (7) for
Upper Channel Assembly
30°
30°
Toward Exit
Toward Entrance
Mount for Upper Channel Lens
4) Verify that the SIDE CHANNEL ASSEMBLIES ROTATE correctly.
Verify that the Side Channel assemblies both rotate 30° from center toward the entrance
of the wash and 30° from center toward the exit of the wash. See the image below.
Nozzle (6) for
Each Side
Channel Assembly
30°
Toward Exit
30°
Side Channel Assembly (2)
Toward Entrance
Mount for Side Channel Lens
26 Belanger, Inc.® *PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL028