Page 48 - FreeStyler® Maintenance Manual
P. 48

®
            MAINTENANCE


            Chapter 2 Preventative Maintenance


            Pumping Station Drive Belt Replacement and Tightening





                    When tightening or replacing the drive belts, check the oil levels. The oil should be half way up
                            the sight gauge. Use ONLY Cat™ approved oil (Belanger® part #1OIL300).
                   1)  At the MCC, turn off the system Main Disconnect and lock it out.
                   2)  Remove the belt guard.
                   3)  Loosen the 4 bolts on the motor support. There are two bolts on the pivot side (A1 and A2) and two
                       bolts on the adjustment side (B1 and B2).






                A1 (Back Side)                                 A2 (Back Side)
               B1 (Front Side)                                 B2 (Front Side)














                                      The above image is a LOWER, RIGHT view
                                      Bolts B1 and B2 are near the adjustment bolt

                   4)  Loosen the adjustment Jam Nut (C).
                   5)  To replace the belts, lower the adjustment screw (D) with a wrench while holding nut (E).
                       If only tightening the belt, go to Step 7.

                            View of Pumping Station LOWER,
                                   RIGHT section



                                                              E

                                                              C

                                                              D












             2-20             Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681               1MANUL222
   43   44   45   46   47   48   49   50   51   52   53